Tyco Sprinkler Tables

Compare Tyco sprinklers by product group, installation configuration, K-factor, connection and temperature rating.

Request a consultation
Tyco TY-FRB sprinkler configurations from the supplied workbook

Swipe or scroll sideways to see all columns.

Standard Spray

Standard Spray
No,Product imageConfigurationK-factor US (Metric)ConnectionTemperature ratings (°C)ApplicationSprinkler finishesEscutcheon / cover finishes
1TYCO TY-FRBTY-FRB Upright / Pendent / Recessed Pendent SIN: TY1131; TY1231; TY2131; TY2231; TY3131; TY3231; TY4131; TY42312.8 (40.3); 4.2 (60.5); 5.6 (80.6); 8.0 (115.2)½″ NPT / ¾″ NPT57 / 68 / 79 / 93 / 141Light / Ordinary Hazard; K2.8: Light Hazard only Quick response; 3 mm bulb. See TFP171.Natural Brass; Chrome Plated; White Polyester; Lead CoatedWhite Coated; Chrome Plated; Brass Plated Escutcheon styles 10 / 20 / 30 / 40.
2TYCO TY-FRBTY-FRB Horizontal / Recessed Horizontal / Vertical Sidewall SIN: TY3331; TY34315.6 (80.6)½″ NPT57 / 68 / 79 / 93 / 141Light / Ordinary Hazard Quick response; 3 mm bulb. See TFP176.Natural Brass; Chrome Plated; White Polyester; Lead CoatedWhite Coated; Chrome Plated; Brass Plated Escutcheon styles 10 / 20.
3TYCO RFII (Royal Flush II)RFII (Royal Flush II) Concealed Pendent SIN: TY3551; TY35315.6 (80.6)½″ NPTSprinkler 68 → Cover 59; Sprinkler 93 → Cover 74Light / Ordinary Hazard Standard / quick response (5 / 3 mm bulb); ½″ vertical adjustment; optional dust and air seal. See TFP181.Not separately statedChrome; Brushed Chrome; Brass; Signal White; Grey White; Custom

Extended Coverage

Extended Coverage
No,Product imageConfigurationK-factor US (Metric)ConnectionTemperature ratings (°C)ApplicationSprinkler finishesEscutcheon / cover finishes
4TYCO EC-5EC-5 Pendent / Recessed Pendent SIN: TY32325.6 (80.6)½″ NPT57; 68Light Hazard. Coverage up to 20 × 20 ft (6.1 × 6.1 m). See TFP228.Natural Brass; Chrome Plated; White PolyesterEscutcheon: White Coated; Chrome Plated; Brass Plated Escutcheon styles 50.
5TYCO EC-5EC-5 Horizontal Sidewall / Recessed Horizontal Sidewall SIN: TY33025.6 (80.6)½″ NPT57; 68; 93Light Hazard. Coverage up to 16 × 24 ft (4.9 × 7.3 m). Commercial occupancies. See TFP298.Natural Brass; Chrome Plated; White PolyesterEscutcheon: White Coated; Chrome Plated; Brass Plated Escutcheon styles 50.
9TYCO CHECCHEC Concealed Horizontal Sidewall SIN: TY43328.0 (115.2)¾″ NPTSprinkler: 68 Cover plate: 59Light Hazard. Coverage up to 16 × 16 ft (4.9 × 4.9 m); concealed installation for architecturally sensitive areas. See TFP265.—Cover: Signal White; Pure White; Chrome Plated; Custom
11TYCO RFII (Royal Flush II)RFII (Royal Flush II) Concealed Pendent SIN: TY35325.6 (80.6)½″ NPTSprinkler / cover: 68 / 59 93 / 74Light Hazard. Maximum 20 × 20 ft (6.1 × 6.1 m), quick-response listing; flat cover plate. See TFP260.—Cover: Chrome Plated; Brass Plated; Signal White; Grey White; Custom

Storage

Storage
No,Product imageConfigurationK-factor US (Metric)ConnectionTemperature ratings (°C)ApplicationSprinkler finishes
1TYCO ESFR-25ESFR-25 Pendent SIN: TY922625.2 (362.9)1″ NPT ISO 7-R174; 101ESFR suppression-mode protection of rack / high-piled storage. Catalog limits: storage up to 40 ft (12.2 m), ceiling up to 45 ft (13.7 m), subject to listing criteria. See TFP312.Natural Brass
5TYCO ESFR-1ESFR-1 Pendent SIN: TY622614.0 (201.6)¾″ NPT74; 101ESFR suppression-mode rack storage protection. May eliminate in-rack sprinklers where permitted by the applicable listing. See TFP318.Natural Brass
7TYCO ULTRA K-17ULTRA K-17 Upright — Specific Application Control Mode, 141°C16.8 (241.9)¾″ NPT141Control-mode storage sprinkler; 5 mm bulb. Catalog directs users to contact TYCO for technical details.Natural Brass
9TYCO ELO-231ELO-231 Pendent / Upright SIN: TY5111; TY5211; TY581111.2 (161.3)½″ NPT; ¾″ NPT74; 100; 141Extra large orifice; solder type. High-challenge storage protection at relatively low required pressures. Intermediate-level use with approved guard and shield. See TFP340.Natural Brass; Chrome Plated; Lead Coated; Wax Coated; Wax over Lead Coated
12TYCO LD (Large Drop)LD (Large Drop) Upright SIN: TY515311.2 (161.3)¾″ NPT68; 93; 141Control-mode protection of high-piled storage; 5 mm bulb. May eliminate in-rack sprinklers for qualifying applications. See TFP335.Natural Brass
14TYCO TY-FRBTY-FRB Pendent / Upright — Intermediate Level SIN: TY3133; TY3231; TY4133; TY42315.6 (80.6); 8.0 (115.2)½″ NPT; ¾″ NPT57; 68; 79; 93; 141Intermediate-level sprinkler; 3 mm bulb. Factory-assembled integral water shield; for locations where sprinkler guards are not required. See TFP356.Natural Brass; Lead Coated

Dry Sprinklers

Dry Sprinklers
No,Product imageConfigurationK-factor US (Metric)ConnectionTemperature ratings (°C)ApplicationSprinkler finishesEscutcheon / cover finishes
2TYCO DS-1 — 3 mm bulbDS-1 — 3 mm bulb Pendent / Upright / Horizontal Sidewall TY3235; TY3135; TY3335; TY3935; TY37355.6 (80.6)¾″ NPT/ 1″ NPT ; ISO 7-R157; 68; 79; 93; 141Light / Ordinary Hazard. For freezing exposure or seasonally drained systems; lengths up to 48″ (1220 mm). Seal prevents water entering the assembly until operation. See TFP510.Natural Brass; Chrome Plated; White PolyesterEscutcheon: White Coated; Chrome Plated; Brass Plated
3TYCO DS-1DS-1 Extended Coverage Horizontal Sidewall TY3338; TY33585.6 (80.6)1″ NPT (standard order); ISO 7-R157; 68Extended coverage, Light Hazard. Coverage up to 16 × 20 ft (4.9 × 6.1 m) or 18 × 16 ft (5.5 × 4.9 m). Lengths up to 48″ (1220 mm). See TFP520.Natural Brass; Chrome Plated; White PolyesterEscutcheon: White Coated; Chrome Plated; Brass Plated
5TYCO DS-1 Stainless SteelDS-1 Stainless Steel Horizontal Sidewall / Extended Coverage Horizontal Sidewall TY3337; TY3357; TY33395.6 (80.6)1″ NPT (standard order); ISO 7-R157; 68; 79; 93; 141; 182Quick- and standard-response options. Corrosive atmospheres; wet-pipe, dry-pipe or preaction installations. Extended coverage up to 16 × 20 ft (4.9 × 6.1 m). See TFP560.Stainless SteelEscutcheon: Stainless Steel
7TYCO DS-2DS-2 Extended Coverage Pendent TY523811.2 (161.3)1″ NPT (standard order); ISO 7-R157; 68; 79; 93; 141Extended coverage, Light / Ordinary Hazard; 3 mm bulb; extra large orifice. For freezing exposure or seasonally drained systems; lengths up to 48″ (1220 mm). See TFP540.Natural Brass; Chrome Plated; White PolyesterEscutcheon: White Coated; Chrome Plated; Brass Plated
8TYCO DS-CDS-C Concealed Pendent TY3535; TY35555.6 (80.6)1″ NPT (standard order); ISO 7-R1Sprinkler / cover: 68 / 59 93 / 74Standard coverage. All hazards (standard response); Light / Ordinary Hazard (quick response). For freezing exposure or seasonally drained systems; lengths up to 48″ (1220 mm). See TFP515.—Cover: Chrome Plated; Brass Plated; White Painted; Custom
10TYCO DS-3DS-3 Extended Coverage Horizontal Sidewall TY533911.2 (161.3)1″ NPT (standard order); ISO 7-R168; 93Extended coverage, Ordinary Hazard; 3 mm bulb. Exterior loading docks and covered areas. For freezing exposure or seasonally drained systems; lengths up to 48″ (1220 mm). See TFP550.Natural Brass; Chrome Plated; White PolyesterEscutcheon: White Coated; Chrome Plated; Brass Plated

Special Purpose

Special Purpose
No,Product imageConfigurationK-factor US (Metric)ConnectionTemperature ratings (°C)ApplicationSprinkler finishesEscutcheon / cover finishes
1TYCO ATTICATTIC BB (Back-to-Back) / HIP / SD (Single Directional) / AP (Attic Plus) SINs: TY4180; TY4181; TY4182; TY3180; TY3181; TY3182; TY2180; TY2181; TY2182; TY3183; TY3184; TY3185; TY3187; TY3190; TY21904.2 (60.5); 5.6 (80.6); 8.0 (115.2)½″ NPT; ¾″ NPT93; 100Specific-application attic protection; wet- or dry-pipe systems. Catalog describes attic widths up to 60 ft (18.3 m) using a single pipe line. Specifications are grouped by family; verify model-specific selection in TFP610.Natural Brass—
2TYCO CC1 — TY1189CC1 — TY1189 Combustible Concealed Space, Upright2.8 (40.3)½″ NPT79Specific-application protection of qualifying Light Hazard combustible and noncombustible concealed spaces. Listed BlazeMaster CPVC applications in combustible concealed areas; see TFP630.Natural Brass—
3TYCO WS — TY3388; TY3488WS — TY3388; TY3488 Window Sprinkler, Horizontal / Pendent Vertical Sidewall5.6 (80.6)½″ NPT68; 93Specific-application glazing protection. Catalog describes assemblies with ratings up to 2 hours; rating depends on the listed glazing assembly and installation criteria. See TFP620.White Polyester Coated; Chrome Plated; Natural Brass—
4TYCO RAVENRAVEN Institutional Pendent / Horizontal Sidewall TY3281; TY3282; TY3381; TY33825.6 (80.6)½″ NPT74Quick response; standard or extended coverage variants. Tamper-resistant design for correctional, detention, mental health care and other commercial facilities. Catalog pressure: 175 psi (12.1 bar). See TFP651.Chrome; WhiteEscutcheon: Chrome; White
5TYCO Issue D QUARTZOIDIssue D QUARTZOID High Temperature, Upright / Pendent TY3191; TY3296; TY4191; TY42925.6 (80.6); 8.0 (115.2)½″ NPT; ¾″ NPT204; 260; 343Standard coverage; all hazards. Extra-high and ultra-high temperature ratings; 11 mm bulb. Corrosion-resistant coating options. See TFP690.Natural Brass; Chrome Plated; Lead Coated—
6TYCO TY-B / TY-FRB — Alternate MaterialsTY-B / TY-FRB — Alternate Materials Vertical Sidewall / Horizontal Sidewall / Recessed Horizontal Sidewall5.6 (80.6)½″ NPT57; 68; 79; 93; 141; 182Corrosion-resistant standard coverage spray sprinklers for commercial occupancies. TY-B: standard response, 5 mm bulb. TY-FRB: quick response, 3 mm bulb. Verify variant-specific temperatures and SINs in TFP680.Materials: Stainless Steel; SMO (stainless-molybdenum alloyed); TitaniumFinish not stated in catalog; escutcheon style 10